Re: Fluke 9010a issue with pod self test

From: Colin Davies <colin.w.davies_at_btopenworld.com>
Date: Tue Sep 23 2008 - 20:47:16 EDT

Having a look at the service manual I'm thinking it might need a new 6820
Pia chip... would I be along the right lines ?

Cheers, Colin

----- Original Message -----
From: "Colin Davies" <colin.w.davies@btopenworld.com>
To: <techtoolslist@flippers.com>
Sent: Wednesday, September 24, 2008 1:18 AM
Subject: [Techtoolslist] Fluke 9010a issue with pod self test

>I just tried my new fluke 9010a with RS-232... passes self test... but when
>I plug a known working 6502 pod in and do a bus test it reports 6502 pod
>error 00 (iirc)....
>
> Is this a relatively easy fix or should I bite the bullet and move the
> rs-232 module over to my working unit ? ( Is that all I have to do ? or
> are there other modifications required to the base unit to accept it ?)
>
> I'd rather fix the faulty unit to be honest, as the worker is in really
> really great condition so I'd like to keep it as a spare and use the other
> new arrival for now.....
>
> Thanks for your help,
> Regards, Colin
> _______________________________________________
> Techtoolslist mailing list
> Techtoolslist@flippers.com
> http://seven.pairlist.net/mailman/listinfo/techtoolslist
> FTP site is: ftp://ftp.flippers.com/TTL/TestEquipment

_______________________________________________
Techtoolslist mailing list
Techtoolslist@flippers.com
http://seven.pairlist.net/mailman/listinfo/techtoolslist
FTP site is: ftp://ftp.flippers.com/TTL/TestEquipment
Received on Tue Sep 23 20:47:12 2008

This archive was generated by hypermail 2.1.8 : Wed Sep 24 2008 - 15:50:00 EDT