Hooked up the 2nd 9010A.  It returns:
R/W ERR @ C000 BTS 12 - LOOP? 
Barry
----------------------
I been having trouble posting to the group...  trying again.
I have 2 non-working 9010A units.  On both they beep once, LEDs flash, then 
nothing.
Hooked up a working 9010A that I borrowed (thanks David).  Bus tests fine.  RAM 
returns the following:
R/W ERR @ C000 BTS 08 - LOOP?
Manual states:
If a RAM failure occurs, carefully examine the diagnostic message.  The RAM 
Test is usually sufficient for deducing the failed component directly.
It then does not explain how to read the message.  :-)  I am new to this, so be 
kind if its a stupid question.
I deduced that there is a Read/Write error at C000.  How do I "deduce" the 
failed component?