Re: Another set of WG 6100 problems!

From: Rodger Boots <rlboots_at_cedar-rapids.net>
Date: Sun Mar 17 2002 - 15:36:50 EST

Use your scope, if possible. No need to risk a monitor on an untested
board.

Dave Langley wrote:
>
> Well it seems the WG was not at fault at all ...
>
> I was testing the boards XY output on my scope and that familiar acrid
> smell returned. looking around one of the 8 pin TL082 amps had smoke
> coming from it!
>
> I changed this (OK robbed it from a partly stripped Tempest PCB) and it
> works. It's been on for an hour so far :o)
>
> This leads me onto the next subject:
>
> What precautions should I take when testing "untested" Tempest PCB's in my
> game. Or am I better off disconnecting the monitor and using my scope.?
>
> Dave Langley
> www.robotron-2084.co.uk
>
> ---------------------------------------------------------------------------
> ** To UNSUBSCRIBE from vectorlist, send a message with "UNSUBSCRIBE" in the
> ** message body to vectorlist-request@synthcom.com. Please direct other
> ** questions, comments, or problems to neil@synthcom.com.

---------------------------------------------------------------------------
** To UNSUBSCRIBE from vectorlist, send a message with "UNSUBSCRIBE" in the
** message body to vectorlist-request@synthcom.com. Please direct other
** questions, comments, or problems to neil@synthcom.com.
Received on Sun Mar 17 12:38:38 2002

This archive was generated by hypermail 2.1.8 : Fri Aug 01 2003 - 00:33:56 EDT