Re: Star Wars problems

From: <MKDUD_at_aol.com>
Date: Wed Sep 10 2003 - 23:29:02 EDT

In a message dated 9/10/2003 3:33:02 PM Eastern Daylight Time,
Jeff_Hendrix@maxtor.com writes:
Most of the time the screen looks normal, but sometimes (either after it's
been on for a while or sometimes when it's first turned on) the screen will
shake and very rapidly change size, but only in the x (horizontal)
direction. All horizontal lines are stable, except getting longer and
shorter. (this is why I don't think the HV unit has anything to do with it).
The output from the board looks fine on my scope (while it simultaneously
looks bad on the monitor).
This is a VERY common problem on Amplifone deflection boards. You'll want to
replace the 10k X and Y size pots. I use mouser #32-1510-10k, I think they are
about 60 cents each.

I wanted to add this to the REVISED deflection faq, but I'm having trouble
editing the damn PDF.....

-MK

---------------------------------------------------------------------------