Dave, Try changing the 150V zenner ( I've got some of these on order ) and try looking at the FAQ documents... excellent stuff.... (I'll try and remember to send you one out - they are 5watt ones - remind me next week with your address) --- Theres a few more parts I guess you could try replacing too (semis) . but not got the bumf to hand at the mo.

If the HV is low, the the electrons from the gun travel slower and so are more easily deflected by the coils, hence why the picture is bigger...

Cheers, Col
  ----- Original Message -----
  From: Pinx
  To: vectorlist@vectorlist.org
  Sent: Friday, April 01, 2005 7:36 PM
  Subject: VECTOR: SW monitor prob...

  Hi guys,
   
  just recently the WG in my SW has developed a problem where the image is massive, so you cant see it all on the screen. I have been told this is "blooming" and so i have just re-capped the HV section, but i still have the problem. Is there anything else on the HV board i should replace to cure this problem ?
   
   
  TIA
   
   
  Pinx

---------------------------------------------------------------------------