Re: troubleshooting G08-003 monitor - HELP

From: Rodger Boots <rlboots_at_cedar-rapids.net>
Date: Sun Jan 01 2006 - 20:56:40 EST

There will be either a braided strap or spring that lays on the outer
coating of the tube and connects to the chassis. This grounds the
outside of the tube.

That grounded coating and a similar one on the inside of the tube (that
connects to the high voltage connector on the side of the tube) forms a
high voltage capacitor.

eyeamnomad@excite.com wrote:

> That was a lot of great info -- thanks. But what is the "diagonal
> strap across tube?"
>
> -- Scott
>

---------------------------------------------------------------------------
** Unsubscribe, subscribe, or view the archives at http://www.vectorlist.org
** Please direct other questions, comments, or problems to chris@westnet.com
Received on Sun Jan 1 22:00:24 2006

This archive was generated by hypermail 2.1.8 : Mon Jan 02 2006 - 21:50:00 EST