Re: 6100 HV help

From: <utahtaper_at_comcast.net>
Date: Sun Feb 05 2006 - 10:44:17 EST

Thanks for the suggestions guys. I'll poke around and report back.
The pots were replaced prior to the first post.

-------------- Original message --------------
From: "simon hanlon" <simonjhanlon@btopenworld.com>

maybe check c911 and c912 around the 555
----- Original Message -----
From: utahtaper
To: vectorlist@vectorlist.org
Sent: Sunday, February 05, 2006 7:32 AM
Subject: VECTOR: 6100 HV help

I have been working on two HV's and both have the exact opposite problem. One has HV at 29KV's(at anode) and the other has HV at 10KV's. Both have been capped and I have been through all resistors and they are all within tolerance. Diodes have been checked and test fine. Transisters are fine. Adjusting the POT(R18? off the top of my head) does nothing to change the voltage in either case. Both display an image just one is huge(10KV) and one I'm afraid of getting X-ray(29KV) exposure to. Is there something I'm missing here? Any suggestions?
Thx,
Jason

No virus found in this outgoing message.
Checked by AVG Free Edition.
Version: 7.1.375 / Virus Database: 267.15.1/250 - Release Date: 02/03/2006
---------------------------------------------------------------------------
** Unsubscribe, subscribe, or view the archives at http://www.vectorlist.org
** Please direct other questions, comments, or problems to chris@westnet.com
Received on Sun Feb 5 10:44:27 2006

This archive was generated by hypermail 2.1.8 : Sun Feb 05 2006 - 14:50:00 EST