couple of things

unless you can find an output winding on the atari power supply
assembly, you'll need an isolation transformer on the AC line.

you will have to experiment with the LC value of the primary of
the chosen HV transformer to get it back in resonace without
the horizontal deflection coil in the circuit, or adjust the
osc frequency up (not a big deal since you don't have to run
at 15khz, in fact, it would be better (noise wise) if you were
supersonic)

the HV on vector monitors is a few KV lower on vector monitors
than raster monitors

you didn't mention if you were going to make this a closed
loop HV supply (with HV regulation)

HV regulation is a GOOD THING.