Re: Tempest monitor has no +25VDC

From: John Robertson <jrr_at_flippers.com>
Date: Tue Aug 28 2001 - 18:38:19 EDT

Cracks in the pin connectors on the main monitor board are the common cause
of this. Re-solder ALL the MOLEX pins on the monitor mother board!

John :-#)#

At 03:16 PM 28/08/2001, you wrote:

>Hello everyone! Im still working on the WG6100 in my tempest machine. I have
>installed the Cap Kit and also replaced the 4 diodes and 2 capicitors on the
>deflection board. They are D100-D103 and C100 & C101 (Thanks Eric!). I also
>tested the connectivity between the black brown and white wire connections
>between the deflector and neck board. They seem to be working. So when i
>test the DC current on J101 i get -25VDC but no +25VDC. I think this may be
>the issue, has anyone else delt with this problem? Thanks in advance for any
>help! -Derek
>
>---------------------------------------------------------------------------
>** To UNSUBSCRIBE from vectorlist, send a message with "UNSUBSCRIBE" in the
>** message body to vectorlist-request@synthcom.com. Please direct other
>** questions, comments, or problems to neil@synthcom.com.

---------------------------------------------------------------------------
** To UNSUBSCRIBE from vectorlist, send a message with "UNSUBSCRIBE" in the
** message body to vectorlist-request@synthcom.com. Please direct other
** questions, comments, or problems to neil@synthcom.com.
Received on Tue Aug 28 15:39:32 2001

This archive was generated by hypermail 2.1.8 : Fri Aug 01 2003 - 00:33:35 EDT