Re: Amplifone again

From: Rodger Boots <rlboots_at_cedar-rapids.net>
Date: Mon Mar 18 2002 - 00:52:31 EST

Try scoping the +24 and -24 supplies to the high voltage power supply.
A lot of high frequency ripple there could indicate bad electrolytics on
the outputs of the regulators.

Joe Bachmann wrote:
>
> More problems.........
>
> I have a HV board which will not produce 19.5kv.
>
> R12 was swapped for a 1k (a Wintron was installed)
>
> It will crank up to around 18kv. I tried replacing R6 with a 4.7k so I could
> crank it further and now all I am getting is a nice ear piercing whine. If I put
> the 3.9k back, all is well. The pot is working as the HV does vary when the pot
> is turned.
>
> Any ideas?
>
> Thanks,
> Joe
>
> ---------------------------------------------------------------------------
> ** To UNSUBSCRIBE from vectorlist, send a message with "UNSUBSCRIBE" in the
> ** message body to vectorlist-request@synthcom.com. Please direct other
> ** questions, comments, or problems to neil@synthcom.com.

---------------------------------------------------------------------------
** To UNSUBSCRIBE from vectorlist, send a message with "UNSUBSCRIBE" in the
** message body to vectorlist-request@synthcom.com. Please direct other
** questions, comments, or problems to neil@synthcom.com.
Received on Sun Mar 17 21:54:26 2002