Re: G05-805 EHT problem

From: Tom McClintock <tomm_at_mgcap.com>
Date: Fri Jun 18 2004 - 16:12:00 EDT

Could be the HV transformer itself. Your HV cage sounds destined to end
up on eBay as 'untested' ;)

tm

Phil Morris wrote:

>
>> Well, if the pot has been replaced, and you are sure it is good, then
>> I would look for cold solder joints on pin connectors, bad grounds, or
>> perhaps a bad capacitor (internal loose connection).
>>
>> John :-#)#
>
>
> Have now checked all that but no luck. Even re-flowed all solder joints.
>
> What puzzles me is why the problem (mostly) goes away as the monitor
> warms up, BUT occasionally momentarily returns (but not nearly as
> prevalent as when the monitor has just been powered on).
>
> I'm tempted to try freezer spray, but given the high voltages involved
> in the EHT I'm kinda wary. :)
>
>
> Phil
>
>
>
> ---------------------------------------------------------------------------
> ** Unsubscribe, subscribe, or view the archives at
> http://www.vectorlist.org
> ** Please direct other questions, comments, or problems to
> chris@westnet.com
>
>
---------------------------------------------------------------------------
** Unsubscribe, subscribe, or view the archives at http://www.vectorlist.org
** Please direct other questions, comments, or problems to chris@westnet.com
Received on Fri Jun 18 16:10:33 2004

This archive was generated by hypermail 2.1.8 : Fri Jun 18 2004 - 17:50:01 EDT