Re: 6100 Questions

From: peter jones <highwayman2000_at_mail.ru>
Date: Sun Apr 29 2007 - 18:50:59 EDT

-----Original Message-----
From: "Ron Matuszak" <ron.matuszak@buckeye-express.com>
To: <vectorlist@vectorlist.org>
Date: Sun, 29 Apr 2007 17:53:33 -0400
Subject: VECTOR: 6100 Questions

> Hi Everyone,
>
> I just had my 6100 working for the first time. When the R702 and R703 burned up. Big flames, about 2in high.. Now when I power it up, I blow F700. I changed the chassis mounted transistors. It still happens. I also tested the Q703/Q704 and they seem to be ok. Is the reading across EBC supposed to be in the 650 range ? I was checking them using my Digital Meter. One lead on the "B" and checking the readings across "E" and "C" with the other lead. Is this the right way to do it? They are the same reading both directions.

they should only read in one direction,
when testing a transistor you should think of it as 2 diodes.

---------------------------------------------------------------------------
** Unsubscribe, subscribe, or view the archives at http://www.vectorlist.org
** Please direct other questions, comments, or problems to chris@westnet.com
Received on Sun Apr 29 18:51:13 2007