Re: Testing HV?

From: Jon Raiford <raiford_at_mindspring.com>
Date: Sun Jun 17 2001 - 10:22:50 EDT

What you should do is measure the secondary outputs off the
transformer. Take a look at the schems at look at the voltages coming off
the right side.

Jon

At 08:46 PM 6/16/2001 -0500, you wrote:
>Hi,
>I've got a couple of black and white vector monitors (one 19V2000 and one
>G05-805), neither of which seems to be putting out any HV. There's no static
>charge on the screens, and no pictures. Both have deflection chatter; the
>Electrohome has glow in the tube neck, and the WG doesn't. I've got an HV
>probe, and my question is where do I check? Clamp the alligator clamp on the
>frame and [carefully!] push the point of the probe under the anode cup? Is
>there any way to measure closer to the "flyback," before the big in-line
>diode to be sure that the diode's not the problem?
>Thanks,
>Lewis
>
>---------------------------------------------------------------------------
>** To UNSUBSCRIBE from vectorlist, send a message with "UNSUBSCRIBE" in the
>** message body to vectorlist-request@synthcom.com. Please direct other
>** questions, comments, or problems to neil@synthcom.com.

---------------------------------------------------------------------------
** To UNSUBSCRIBE from vectorlist, send a message with "UNSUBSCRIBE" in the
** message body to vectorlist-request@synthcom.com. Please direct other
** questions, comments, or problems to neil@synthcom.com.
Received on Sun Jun 17 10:39:40 2001

This archive was generated by hypermail 2.1.8 : Fri Aug 01 2003 - 00:31:48 EDT