RE: Question regarding 19K6100 HV Transformer....

From: Stempak Arcadius-ASTEMPA1 <ASTEMPA1_at_motorola.com>
Date: Wed Sep 11 2002 - 00:12:45 EDT

Greg,
*****

 Well thanks again, for the advice and this is
where my problem lies, as I forgot to mention
the obvious, which is, that even though I can
adjust the HV as previously stated, and the Monitor
displays a decent clear picture / focus, I can not get
the B+ Voltage to ever reach 180VDC. In fact the B+ will
only range around 135 VDC to around 170 VDC, or so.

 Also I already Raplaced All the ELECTOLYTIC CAPS, as well
as TRANSISTORS Q900, Q901, Q902 and Q903, as well as
a few Resistors. Also Verified All Wiring Connections,
etc,,, as well as checked and reflowed All Solder Joints.

 Obviously I would presume that if B+ is low so will the
HV, but have not for the life of me, been able to figure
out what could be causing this to occur in the first place.

 Should I recheck the Low Voltage Boardset ???

Arcadius.......... :-)

-----Original Message-----
From: Gregg Woodcock [mailto:woodcock@sisna.com]
Sent: Tuesday, September 10, 2002 10:43 PM
To: vectorlist@synthcom.com
Subject: Re: VECTOR: Question regarding 19K6100 HV Transformer....

----- Original Message -----
From: "Stempak Arcadius-ASTEMPA1" <ASTEMPA1@motorola.com>
To: <vectorlist@synthcom.com>
Cc: "Stempak Arcadius-ASTEMPA1" <ASTEMPA1@motorola.com>
Sent: Tuesday, September 10, 2002 3:36 PM
Subject: RE: VECTOR: Question regarding 19K6100 HV Transformer....

> Greg,
> ^^^^^
>
> Thank you once again, appreciate the
> information and have one last question on
> this Topic, if you do not mind.
>
> Since my MAX HV Output only goes up to 17.8 KV
> Yet the monitor appears to function normally,
> from what I can tell at around 16.2KV should I
> set the 25K Pot in the HV Cage to MAX, which would
> then more or less bring the HV to almost the
> reccomended 19.5KV as stated in the Wells Gardner
> Vector Manual or should I just leave things alone ???

Set the B+ voltage (orange wire, I believe) to 180VDC (I think that is the
correct voltage; better double check what the schematics say for B+) by
adjusting that pot. Then the HVT control should be in suitable range.

---------------------------------------------------------------------------
** To UNSUBSCRIBE from vectorlist, send a message with "UNSUBSCRIBE" in the
** message body to vectorlist-request@synthcom.com. Please direct other
** questions, comments, or problems to vectorlist-owner@synthcom.com.
---------------------------------------------------------------------------
** To UNSUBSCRIBE from vectorlist, send a message with "UNSUBSCRIBE" in the
** message body to vectorlist-request@synthcom.com. Please direct other
** questions, comments, or problems to vectorlist-owner@synthcom.com.
Received on Tue Sep 10 21:36:46 2002

This archive was generated by hypermail 2.1.8 : Fri Aug 01 2003 - 00:34:08 EDT