RE: Question regarding 19K6100 HV Transformer....

From: Jon Raiford <raiford_at_mindspring.com>
Date: Wed Sep 11 2002 - 09:13:43 EDT

Have you replaced the pot itself yet?

Jon

At 11:12 PM 9/10/2002 -0500, you wrote:
>Greg,
>*****
>
>
> Well thanks again, for the advice and this is
>where my problem lies, as I forgot to mention
>the obvious, which is, that even though I can
>adjust the HV as previously stated, and the Monitor
>displays a decent clear picture / focus, I can not get
>the B+ Voltage to ever reach 180VDC. In fact the B+ will
>only range around 135 VDC to around 170 VDC, or so.
>
> Also I already Raplaced All the ELECTOLYTIC CAPS, as well
>as TRANSISTORS Q900, Q901, Q902 and Q903, as well as
>a few Resistors. Also Verified All Wiring Connections,
>etc,,, as well as checked and reflowed All Solder Joints.
>
> Obviously I would presume that if B+ is low so will the
>HV, but have not for the life of me, been able to figure
>out what could be causing this to occur in the first place.
>
> Should I recheck the Low Voltage Boardset ???
>
>
>
>Arcadius.......... :-)
>
>-----Original Message-----
>From: Gregg Woodcock [mailto:woodcock@sisna.com]
>Sent: Tuesday, September 10, 2002 10:43 PM
>To: vectorlist@synthcom.com
>Subject: Re: VECTOR: Question regarding 19K6100 HV Transformer....
>
>
>
>----- Original Message -----
>From: "Stempak Arcadius-ASTEMPA1" <ASTEMPA1@motorola.com>
>To: <vectorlist@synthcom.com>
>Cc: "Stempak Arcadius-ASTEMPA1" <ASTEMPA1@motorola.com>
>Sent: Tuesday, September 10, 2002 3:36 PM
>Subject: RE: VECTOR: Question regarding 19K6100 HV Transformer....
>
>
>> Greg,
>> ^^^^^
>>
>> Thank you once again, appreciate the
>> information and have one last question on
>> this Topic, if you do not mind.
>>
>> Since my MAX HV Output only goes up to 17.8 KV
>> Yet the monitor appears to function normally,
>> from what I can tell at around 16.2KV should I
>> set the 25K Pot in the HV Cage to MAX, which would
>> then more or less bring the HV to almost the
>> reccomended 19.5KV as stated in the Wells Gardner
>> Vector Manual or should I just leave things alone ???
>
>Set the B+ voltage (orange wire, I believe) to 180VDC (I think that is the
>correct voltage; better double check what the schematics say for B+) by
>adjusting that pot. Then the HVT control should be in suitable range.
>
>---------------------------------------------------------------------------
>** To UNSUBSCRIBE from vectorlist, send a message with "UNSUBSCRIBE" in the
>** message body to vectorlist-request@synthcom.com. Please direct other
>** questions, comments, or problems to vectorlist-owner@synthcom.com.
>---------------------------------------------------------------------------
>** To UNSUBSCRIBE from vectorlist, send a message with "UNSUBSCRIBE" in the
>** message body to vectorlist-request@synthcom.com. Please direct other
>** questions, comments, or problems to vectorlist-owner@synthcom.com.

---------------------------------------------------------------------------
** To UNSUBSCRIBE from vectorlist, send a message with "UNSUBSCRIBE" in the
** message body to vectorlist-request@synthcom.com. Please direct other
** questions, comments, or problems to vectorlist-owner@synthcom.com.
Received on Wed Sep 11 06:33:19 2002

This archive was generated by hypermail 2.1.8 : Fri Aug 01 2003 - 00:34:08 EDT