Re: Arcing in tube on WG 19K6100 monitor

From: Kurt Mahan <kmahan_at_xmission.com>
Date: Sun Mar 16 2003 - 20:47:01 EST

Sounds like (to quote someone years ago on the list) "You let the vacuum out".

Kurt
kmahan@xmission.com

> After moving my Space Duel, the (WG 19K6101) monitor wouldn't work. I took a peek in the back and saw a bunch of arcing inside the neck of the CRT just forward of the convergence rings. I swapped the tube with my spare 6100 and the problem follows the tube. Both 6100 chassis, HV units, and neckboards are good.
>
> So, does this sound like a catastrophic tube failure or something that perhaps a tube rejuvination could fix? Any ideas on what exactly might cause this or possible remedies?
>
> Thanks in advance,
>
> - Erik
---------------------------------------------------------------------------
** To UNSUBSCRIBE from vectorlist, send a message with "UNSUBSCRIBE" in the
** message body to vectorlist-request@synthcom.com. Please direct other
** questions, comments, or problems to vectorlist-owner@synthcom.com.
Received on Sun Mar 16 17:47:08 2003