Re: G08 input voltages

From: <js_at_cimmeri.com>
Date: Mon Dec 15 2008 - 16:08:06 EST

Only if it has 90VCT taps.

 JS

tomm@bhpllc.com wrote:

>I'm pretty certain *any* Sega transformer (raster or vector) is the same,
>and thus appropriate for a G08 setup.
>
>
>tm
>
>
>
>>It's a very bad idea.
>>
>>I have a 90VCT toroid transformer that works well with the G08 if anyone
>>is interested.
>>
>> JS
>>
>>utahtaper wrote:
>>
>>
>>
>>>A couple years ago I bought a Skydiver that was converted into Star
>>>Trek. The cabinet was falling apart and I ended up parting it. I
>>>suspect they tapped into the isolation transformer to run the G08
>>>from. >From what I've been told the G08 takes 90VAC(two lines of
>>>45VAC). This transformer is outputting 120VAC(Two lines of 60VAC).
>>>Anyone out there know if this monitor can handle this voltage? It
>>>would seem it's a bad idea even though the converted game had been
>>>running that way for who knows how long. I was hoping to try it out
>>>with my ZVG setup.
>>>
>>>
>>
>>
>
>
>---------------------------------------------------------------------------