Re: Need help with my G08 in my Sega Star Trek SOS

From: <kstillinger_at_sc.rr.com>
Date: Fri Dec 14 2012 - 20:05:35 EST

It looks like the HV protection is trying to kick in.

You could check for a solid 100V on the HV regulator board.
Other than that, you could tweak one or more of those pots on the HV cage.

Kerry

---- Grant Thienemann <grant.thienemann@gmail.com> wrote:
> Hey Guys,
>
> My G08 started doing something really weird today and I don't have a
> clue what is causing it! Here is a video of whats it doing:
>
> http://youtu.be/3eRv3aQNZ84
>
> I can hear the vector monitor "chattering" when it does that, I did
> change the transformer so that the monitor is only getting 45V but the
> monitor was doing this BEFORE I did that upgrade.
>
> Any help would be greatly appreciated! Could this be a power supply
> issue? I'm made sure all the connections are tight. Do I need to do a
> cap kit on the chassis?
>
> Thank you for looking!
> -Grant
> ---------------------------------------------------------------------------
> ** Unsubscribe, subscribe, or view the archives at http://www.vectorlist.org
> ** Please direct other questions, comments, or problems to chris@westnet.com

---------------------------------------------------------------------------
** Unsubscribe, subscribe, or view the archives at http://www.vectorlist.org
** Please direct other questions, comments, or problems to chris@westnet.com
Received on Fri Dec 14 20:05:46 2012

This archive was generated by hypermail 2.1.8 : Sat Dec 15 2012 - 07:50:00 EST